Home > Engineering > Electrical Engineering > Volume-3 > Issue-5 > Design of Earthing System for 230 kV High Voltage Substation by ETAP 12.6 Software

Design of Earthing System for 230 kV High Voltage Substation by ETAP 12.6 Software

Call for Papers

Volume-8 | Issue-6

Last date : 27-Dec-2024

Best International Journal
Open Access | Peer Reviewed | Best International Journal | Indexing & IF | 24*7 Support | Dedicated Qualified Team | Rapid Publication Process | International Editor, Reviewer Board | Attractive User Interface with Easy Navigation

Journal Type : Open Access

First Update : Within 7 Days after submittion

Submit Paper Online

For Author

Research Area


Design of Earthing System for 230 kV High Voltage Substation by ETAP 12.6 Software


Khin Thuzar Soe | Thet Mon Aye | Aye Aye Mon



Khin Thuzar Soe | Thet Mon Aye | Aye Aye Mon "Design of Earthing System for 230 kV High Voltage Substation by ETAP 12.6 Software" Published in International Journal of Trend in Scientific Research and Development (ijtsrd), ISSN: 2456-6470, Volume-3 | Issue-5, August 2019, pp.1840-1843, URL: https://www.ijtsrd.com/papers/ijtsrd26747.pdf

The design of earthing system for 230 kV substation is challenging task. A safety is one major concern in the operation and design of an electrical power system. This Paper is to provide information pertinent to safe earthing practice in substation design and to establish the safe limits of potential difference under normal and fault conditions. Substation earthing system design requires calculating of parameter such as touch and step voltage criteria for safety, grid resistance, maximum grid current, earth resistance, minimum conductor size and electrode size, maximum fault current level and soil resistivity. Soil resistivity is a major factor influencing substation grid design. In this paper, design of earthing grid for Square configuration to obtain the minimum cost and safety. Finally, simulation results were carried out using ETAP 12.6 software. This paper mentions the method proposed for substation earthing is in accordance with IEEE Std 80-2000.

Substation design, touch and step voltage, soil resistivity, ETAP 12.6 software, grounding grid


IJTSRD26747
Volume-3 | Issue-5, August 2019
1840-1843
IJTSRD | www.ijtsrd.com | E-ISSN 2456-6470
Copyright © 2019 by author(s) and International Journal of Trend in Scientific Research and Development Journal. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0) (http://creativecommons.org/licenses/by/4.0)

International Journal of Trend in Scientific Research and Development - IJTSRD having online ISSN 2456-6470. IJTSRD is a leading Open Access, Peer-Reviewed International Journal which provides rapid publication of your research articles and aims to promote the theory and practice along with knowledge sharing between researchers, developers, engineers, students, and practitioners working in and around the world in many areas like Sciences, Technology, Innovation, Engineering, Agriculture, Management and many more and it is recommended by all Universities, review articles and short communications in all subjects. IJTSRD running an International Journal who are proving quality publication of peer reviewed and refereed international journals from diverse fields that emphasizes new research, development and their applications. IJTSRD provides an online access to exchange your research work, technical notes & surveying results among professionals throughout the world in e-journals. IJTSRD is a fastest growing and dynamic professional organization. The aim of this organization is to provide access not only to world class research resources, but through its professionals aim to bring in a significant transformation in the real of open access journals and online publishing.

Thomson Reuters
Google Scholer
Academia.edu

ResearchBib
Scribd.com
archive

PdfSR
issuu
Slideshare

WorldJournalAlerts
Twitter
Linkedin